Suction Strainers — Suction Strainer Manufacturer in Taiwan
A suction strainer keeps debris out of the pump at the draw end of a suction line. We make three body styles in plated steel, plus cast-iron foot valves where the line also has to hold its prime.
Strainers, plated
| Size | Round, shank end | Round, Fe NPSM | Square, Fe NPSM | Skimmer bottom hole | Pkg qty |
|---|---|---|---|---|---|
| 1-1/2″ | — | FGRH150 | FGSH150 | FGBH150 | 32 |
| 2″ | FGRH200S | FGRH200 | FGSH200 | FGBH200 | 18 |
| 2-1/2″ | — | FGRH250 | FGSH250 | FGBH250 | 18 |
| 3″ | FGRH300S | FGRH300 | FGSH300 | FGBH300 | 18 |
| 4″ | FGRH400S | FGRH400 | FGSH400 | FGBH400 | 18 |
| 6″ | FGRH600S | FGRH600 | FGSH600 | FGBH600 | 6 |
- Round type, shank end (FGRH…S) — pushes into the hose and clamps, so it suits a hose that is already terminated with a plain end.
- Round type, female NPSM (FGRH) — threads onto a male end. The general-purpose choice.
- Square type, female NPSM (FGSH) — the flatter body sits closer to the bottom of a shallow sump without lifting the intake.
- Skimmer bottom hole type (FGBH) — draws from above the floor of the tank so settled solids are not pulled in. Use it where the bottom of the vessel carries sediment.
Foot valves, sand cast and painted
A foot valve is a strainer with a non-return valve in the body: it keeps the suction line full when the pump stops, so the pump does not have to re-prime on every start.
| Size | Screwed end | Flanged end |
|---|---|---|
| 3/4″ | FHSV006 | — |
| 1″ | FHSV010 | — |
| 1-1/4″ | FHSV012 | — |
| 1-1/2″ | FHSV015 | — |
| 2″ | FHSV020 | — |
| 2-1/2″ | FHSV025 | — |
| 3″ | FHSV030 | FHFV030 |
| 4″ | FHSV040 | FHFV040 |
| 5″ | FHSV050 | FHFV050 |
| 6″ | FHSV060 | FHFV060 |
| 8″ | — | FHFV080 |
| 10″ | — | FHFV100 |
Sizing the strainer, not just the thread
The open area of the strainer should be several times the bore of the line. A strainer that matches the pipe size on paper can still starve the pump once the screen is partly blinded, which shows up as cavitation rather than as an obvious blockage. If the medium carries fibre or leaf matter, size up a nominal step and plan on cleaning intervals.
On the hose side, suction service needs a hose that will not collapse: see our B20 oil suction and delivery hose, which carries a helix wire for exactly that reason.
What we need in order to quote
- Size, and whether the end is a hose shank or female NPSM thread
- Body style — round, square or skimmer
- Whether you need a foot valve rather than a plain strainer, and screwed or flanged
- The medium, so we can advise on screen opening
Send us the sizes and we will quote factory-direct.
Inquiry
Sunze Rubber Industrial Co., Ltd.


7Fl. No.9 Lane 83 Sec.1 Chung Shan N. Rd. Taipei. Taiwan